    Fix SIGBUS due to unaligned access · 748a652f
    Veselin Georgiev authored
    Update RAPIDJSON_ALIGN() to always align on an 8-byte boundary
    unless otherwise overridden.
    
    On some platforms (such as ARM), 64-bit items (such as doubles and
    64-bit integers) must be aligned to an 8 byte address, even though the
    architecture is only 32-bits. On these platforms, MemoryPoolAllocator
    must match the malloc() behavior and return a 8 byte aligned allocation.
    This eliminates any alignment issues that may occur at the expense of
    additional memory overhead.
    
    Failure to do so caused a SIGBUS signal when calling
    GenericValue::SetNull(). The size of the data_ member of the
    GenericValue class is 16 bytes in 32-bit mode and its constructor
    requires an 8-byte aligned access.
    
    While parsing a JSON formatted string using Document::ParseStream(), a
    stack object containing GenericValue items was constructed. Since the
    stack was 8-byte aligned, the constructor calls would succeed. When the
    lifetime of the object ends, SetObjectRaw() is invoked. This triggered
    an allocation with 4-byte alignment to which the previously 8-byte
    aligned GenericValue array was copied. After this, any call to a
    GenericValue API that triggered the constructor and thus the placement
    new operation on the Data type member would trigger a SIGBUS.
    Signed-off-by: 's avatarVeselin Georgiev <veselin.georgiev@garmin.com>
    Signed-off-by: 's avatarJoshua Watt <Joshua.Watt@garmin.com>